5 things about Gas Turbine Inlet Air Cooling (GTIAC) you need to know

 GTIAC is a cost-effective optimised solution.

Today, there are various ways to enhance the power output of gas turbines. The most cost-effective means is Gas Turbine Inlet Air Cooling (GTIAC). This technology can increase a gas turbine generator’s output to produce 30%+ more electricity at a fraction of the cost of a new gas turbine generator.

The most consistently successful method of GTIAC is mechanical cooling. Based on proven water-chiller and heat-exchanger technologies, this method delivers the
cooling capacity, dependably and consistently to obtain optimal output from the gas turbine. Operating the turbine at the relatively constant conditions offered
by mechanical cooling can improve turbine life and lower maintenance costs.

Five important things about Gas Turbine Inlet Air Cooling (GTIAC) you need to know:

1. Selecting intake temperature

For GTIAC, a commonly considered bell mouth intake air temperature is 15oC. This may not be the optimal intake temperature for all GTIAC installations. In locations with high humidity, you need to consider the level of “sensible” cooling that is economically optimal. Otherwise, chiller capacity will be used in condensing the water vapor in the air.

2. Determining design point

When selecting a design point for GTIAC, it is important to remember that relative humidity (RH) and ambient temperature are counter cyclical. The RH at any location drops with an increase in ambient dry bulb temperature and vice versa. If the design set point is selected based on the highest RH and highest dry bulb temperature at a location, it would result in a vastly oversized chilling plant.

3. Choosing chilling coil

Optimal chilling coil design is crucial. If the chilling coil size in the filter house is too small, the chilled water temperature required to achieve the desired inlet air temperature would be low and the chilled water delta T would be small. To produce this chilled water at lower temperature and small delta T, a larger capacity chiller plant is required, with higher than necessary parasitic load.

4. Configuring multiple chillers

Connecting multiple chillers in series counter flow configuration has a significant impact on system efficiency. This type of cascading configuration can reduce
the compressor work needed by each chiller, improving the overall chiller system efficiency by as much as 8%.

5. Designing holistically

In many projects, the scope of supply responsibility for chiller plant and coils lies with separate vendors. This results in a GTIAC system that does not have optimal lifetime performance. It is vital to take a holistic approach to GTIAC system design from the start.

Join Asian Power community
Since you're here...

...there are many ways you can work with us to advertise your company and connect to your customers. Our team can help you dight and create an advertising campaign, in print and digital, on this website and in print magazine.

We can also organize a real life or digital event for you and find thought leader speakers as well as industry leaders, who could be your potential partners, to join the event. We also run some awards programmes which give you an opportunity to be recognized for your achievements during the year and you can join this as a participant or a sponsor.

Let us help you drive your business forward with a good partnership!

Exclusives

India removes licence requirement to build transmission lines for bulk consumers
The rule applies to those with at least 25 MW of load for inter-state connection and at least 10 MW for intra-state.
NEFIN Group works double time to catch up on projects
CEO Glenn Lim explains how a delay turned out good as the company aims to reach 667 MW of capacity by 2026.
Summit Power International provides vital LNG support to Bangladesh
Without cross-border electricity supply, LNG is needed by a country facing geographical constraints to deploy renewables.